SHR 3D CT 190 / 240 / 320

CT160

The SHAKE SHR 3D CT 190 / 240 / 320 is a partially automated industrial CT. It is modular and flexible and can be used in the 1-2-3D metrology. The dimensional measurement technique is extended to the measurement of surfaces and micro structures.

Device Description

CT160 190The unit can be supplied in 3 versions corresponding to a penetration power of 190/240 or 320 kV. In the device, a stable granite plate is installed, which is used for vibration suppression. By this very stable construction high-precision measurements are possible. The system has an optional power-operated door which implemented via safety contacts the safety circuit. The device is a protection unit and like all our systems in accordance with the TÜV RöV tested and certified.An installed inside camera supports the process monitoring.The output power of the plant can be controlled by up to 320 kV. The resolution is <1.5 microns.

What can be measured using our SHAKE SHR CT 190 / 240 / 320 ?


SHAKE SHR 3D CT 130

The industrial X-Ray CT provides an unlimited range of applications. X-Rays also maps concealed or internal structures. Thus, the CT can create a complete digital 3D image of  the specimen. Possible evaluations are:

  • Dimensional Measurement (wall thickness, 3D target-actual comparison)
  • Reverse Engineering (return to CAD data)
  • Analysis of casting defects (pores, blowholes, cracks, inclusions, core mismatch)
  • Failure analysis example assembly errors and seals
  • Weld inspection (plastic, aluminum, steel
  • Initial inspection (casting quality, target-actual comparison)
  • Serial testing or serial monitoring e.g. in casting
  • Investigation of composite materials fiberbundle layer, delamination

Advantage and benefit of the SHAKE SHR 3D CT 190 / 240 / 320

Turm-Scan-SHAKE-3D-CT-50

The main advantage of the SHAKE SHR 3D CT 130 / 160 is the determination of 3D information to internal and unknown geometries.

Turm-Scan-SHAKE-3D-CT-70

Blowholes can be determined in its position and size and so the X-Ray examination are supplemented by important depth information.

Turm-Scan-SHAKE-3D-CT-70-3

Based on the present data set further evaluations such as wall thickness requirements, measurement of inner and outer contours, and extractions as a surface model for standard CAD programs are possible.

 

SHAKE SHR 3D CT 160 Objekt

Dimensions SHAKE SHR 3D CT 190 / 240 / 320

The dimensions and weight of the system require a permissible floor or ceiling load at the installation site.

Specification SHAKE SHR 3D CT 190 / 240 / 320

By further request we will send you more detailed informations.

SHR CT 50

manufacturing world japan 2020Auf der 5ten MANUFACTURING WORLD Nagoya, vom 9.-11. September 2020 zeigte unser Partner QVI Japan, neben weiteren Geräten unser SHR CT 50.

Control

control 2019

Die Control in Stuttgart stellt für uns eine der wichtigsten Messen dar. Wir freuen uns, sobald es wieder vollumfänglich möglich ist Messen zu besuchen, Sie auf der Control begrüssen zu können. 

SHR 3D CT 70

SHR 3D CT 70Mit dem neuen SHR 3D CT 70 zeigte die SHR Shake GmbH auf der Control innovative kompakte CT-Technik im Kleinformat. Das Desktop taugliche Gerät überzeugt mit Leistungsdaten aus der Oberklasse. mehr lesen

Seminar für
Strahlenschutz 2020

Das Norddeutsche Seminar für Strahlenschutz in den Universitäten in Kiel und Greifswald hat die Termine für 2020 bekannt gegeben. Shake unterstützt mit seinen Experten ggf. bei allen Fragen rund um die Röntgen-Technik.

The North German Seminar for Radiation Protection in the Universities of Kiel and Greifswald has announced the dates for 2020. Shake supports with his experts if necessary with all questions around the x-ray technique.
Weitere/More Informationen

Shake CT-Filme

SHAKE CT130 3DCT130 3D und Volume Graphics Analyse

Invertierung AbdruckloeffelDateninvertierung zur weiteren Bearbeitung

dental ct gesamtHybridCT SHR 3D CT 130

streifenlicht scan abdruckHybriDentCT

Scan einer toten MausComputertomographie einer Maus

SHAKE CT 130
SHAKE SHR 3D CT 130

SHAKE Inline CT 50
SHAKE Inline CT 50

shake rowix
Ro Wi-X

SHR CT 130 shake

Übersicht Shake GmbH

Go to top