SHAKE SHR 2D 50 / 70


SHAKE SHR 3D CT 50 vertikal

Our experience in X-ray technology

Due to 60 years of expertise in X-ray technology, we are fully able to conceive X-ray equipment itself. The SHR V (V = vertical) series has been designed for rapid radiographic simple 2D tasks. Both as a stand-alone solution or in conjunction with our software SHR element, it is possible to realize economically complex solutions. The SHR SHAKE 2D 50 / 70 set is a small compact 2D X-ray machine for analysis and quality control. It is modular and flexible in the 1-2D metrology. The dimensional measurement technology is extended by the measurement of surfaces and microstructures. The device is available in two variants (50kV and 70kV).

Device Description

The SHR SHAKE 2D 50 / 70 set is one of the smallest industrial X-ray machines in the world. It was designed for two-dimensional measurement and workpiece examinations or to crack and blowhole identification. With the high resolution 2D SHR 50 / 70 set XRay-System objects can be irradiated up to a diameter of 50 mm. In conjunction with the quick reconstruction "on-the-fly" dimensional volume models are calculated. Further processing of the data, for example, comparative measurements carried out, highly accurate on virtual workpiece (CAD). Alternatively, also the classical dimensional evaluation is possible. The device is a full protection unit and like all our systems in accordance with the TÜV RöV tested and certified.

What can be measured using our SHAKE SHR 2D CT 50 / 70 ?

The industrial X-Ray CT provides an unlimited range of applications. X-Rays also maps concealed or internal structures. Thus, the CT can create a complete digital 2D image of  the specimen. Possible evaluations are:

  • Dimensional Measurement (wall thickness, 2D target-actual comparison)
  • Reverse Engineering (return to CAD data)
  • Analysis of casting defects (pores, blowholes, cracks, inclusions, core mismatch)
  • Failure analysis example assembly errors and seals
  • Weld inspection (plastic, aluminum, steel)
  • Initial inspection (casting quality, target-actual comparison)
  • Serial testing or serial monitoring e.g. in castings
  • Investigation of composite materials fiber bundle layer, delamination

Advantage and benefit of the SHAKE SHR 2D CT 50 / 70

The main advantage of the SHAKE SHR 2D CT 50 / 70 is the determination of 2D information to internal and unknown geometries. Blowholes can be determined in its position and size and so the X-Ray examination are supplemented by important depth information. Based on the present data set further evaluations such as wall thickness requirements, measurement of inner and outer contours, and extractions as a surface model for standard CAD programs are possible.

Dimensions of the SHAKE SHR 2D 50 / 70

The dimensions of the device allow the use in nearly every workplace.

How works the SHAKE SHR 2D 50 / 70 ?

In a shielded against X-ray housing, the test object is X-rayed. In opposite of the X-ray source, the detector is positioned.

Specification SHAKE SHR 2D CT 50 / 70

  SHR 2D 50 SHR 2D 70
Strahlerleistung 50kV 70kV
Strahlerstrom 1mA 1mA
Leistung 50 W 50 W
Fokusspot < 50 μm < 50 μm
Detektorfläche 1024 x 1024 Pixel -
Pixelgröße 48 μm 48 μm/100 μm
Detektorgröße 50 x 50 mm 100 x 100 mm
Zoom 1,3 - 2,5 fach 1,3 - 2,5 fach
Objektgröße bis 50 mm Durchmesser bis 100 mm Durchmesser
Abmessungen 500 x 500 x 1200 mm 500 x 500 x 1200 mm
Gewicht ca.150 Kg ca. 150Kg

SHR CT 50

manufacturing world japan 2020Auf der 5ten MANUFACTURING WORLD Nagoya, vom 9.-11. September 2020 zeigte unser Partner QVI Japan, neben weiteren Geräten unser SHR CT 50.

Control

control 2019

Die Control in Stuttgart stellt für uns eine der wichtigsten Messen dar. Wir freuen uns, sobald es wieder vollumfänglich möglich ist Messen zu besuchen, Sie auf der Control begrüssen zu können. 

SHR 3D CT 70

SHR 3D CT 70Mit dem neuen SHR 3D CT 70 zeigte die SHR Shake GmbH auf der Control innovative kompakte CT-Technik im Kleinformat. Das Desktop taugliche Gerät überzeugt mit Leistungsdaten aus der Oberklasse. mehr lesen

Seminar für
Strahlenschutz 2020

Das Norddeutsche Seminar für Strahlenschutz in den Universitäten in Kiel und Greifswald hat die Termine für 2020 bekannt gegeben. Shake unterstützt mit seinen Experten ggf. bei allen Fragen rund um die Röntgen-Technik.

The North German Seminar for Radiation Protection in the Universities of Kiel and Greifswald has announced the dates for 2020. Shake supports with his experts if necessary with all questions around the x-ray technique.
Weitere/More Informationen

Shake CT-Filme

SHAKE CT130 3DCT130 3D und Volume Graphics Analyse

Invertierung AbdruckloeffelDateninvertierung zur weiteren Bearbeitung

dental ct gesamtHybridCT SHR 3D CT 130

streifenlicht scan abdruckHybriDentCT

Scan einer toten MausComputertomographie einer Maus

SHAKE CT 130
SHAKE SHR 3D CT 130

SHAKE Inline CT 50
SHAKE Inline CT 50

shake rowix
Ro Wi-X

SHR CT 130 shake

Übersicht Shake GmbH

Go to top